Standards & Compliance
The standards and regulations that govern FRP grating specification and design.
The standards and regulations that govern FRP grating specification and design.
Standard and test report pages
How these standards affect a grating order
The pages above summarise the standards that most often appear in enquiries: DIN 24537 for grating dimensions and tolerances, RAL-GZ 638 for the German quality mark, EN ISO 14122 for access to machinery, and OSHA 1910 for walking surfaces in the United States. A specification is only meaningful when the load, span, fixing and surface requirements are fixed together, so each of these pages lists the clauses that change a design. Test evidence held for the current range includes an ASTM F3059 pedestrian surface report (211122012SHF-001) and an ISO 9001:2000 certificate under GB/T19001-2000 idt; copies are supplied with quotations on request.
- DIN 24537-3: Plastic Gratings Standard
- EN ISO 14122: Permanent Access to Machinery
- OSHA 1910 Subpart D: Walking-Working Surfaces
- RAL GZ 638: Grating Quality Assurance
If a project names a standard that is not listed here, send the clause and the drawing — the factory checks it against the range before quoting rather than assuming compliance.