FRP Grating in a Brazilian Pulp Mill: Bleach, ClO2 and Channel

Project Case Studies
Direct Answer

Brazilian pulp mills run chlorine dioxide, hot caustic and bleach liquor on the same floor. Vinyl ester FRP grating takes the acid, the alkali and the tropical humidity without a paint cycle, without hot-work permits and without pulling the washers offline for panel swaps during the monthly bleach wash-down.

  • Best for: Bleach plant walkways, ClO2 supply platforms, effluent channels
  • Specify when: Vinyl ester, 38 mm molded, grit top, pultruded 50 mm for long spans
  • Key spec: Vinyl ester 38 mm, 19.5 kg/m2, SS316 clips, sealed cut edges

A Brazilian pulp mill in the Southeast ran steel grating in three corrosive spots: the walkways around the bleach plant washers, the platform at the chlorine dioxide supply cabinet, and the grating over the alkaline effluent channel. Steel corroded through in two to three years under the bleach chemistry, and each replacement needed a tank-farm shutdown that the mill could rarely spare. We supplied vinyl ester FRP grating on all three routes, and none of them now carries a coating program, a washer-stop or a recurring panel-swap schedule.

Site conditions and the three project cases

Why steel fails in a bleach plant

A bleach plant stacks three attacks at once: hot chlorine dioxide liquor from the washers, caustic soda used in extraction stages, and tropical humidity that never dries out. Steel grating sweats, the mesh holds bleach residue, and the bar ends corrode first where water runs off the frame. Galvanized steel is gone in two to three years; stainless steel pitting starts at welds and cut edges. The effluent channel adds alkaline liquor at 60 to 70 C, which accelerates every corrosion mechanism. Steel in this service rarely lasts past three years, and a panel swap means a washer stop.

Case 1: bleach washer walkway

Around the bleach washers, operators walk out to sample liquor and adjust shower valves. We supplied 38 mm molded FRP grating in vinyl ester resin with grit top surface, 900 mm support span, clipped to existing steel stringers with SS316 clips. Vinyl ester is the resin choice here because chlorine dioxide and hot caustic land directly on the mesh during shower calibration. Grit top keeps boots planted on a permanently damp floor, and at 19.5 kg per square meter the panel is light enough for two operators to lift out during a washer wash-down.

Case 2: chlorine dioxide supply platform

At the chlorine dioxide supply cabinet, maintenance needed a small platform to reach the valve manifold and the leak detector. We supplied pultruded I-profile grating, 50 mm deep, in vinyl ester, as removable sections clipped to the cabinet frame. Pultruded profiles span wider than molded panels, which suited the offset from the cabinet to the wall. The platform is non-sparking, which matters in a chlorine dioxide zone, and the sections lift off in minutes when the cabinet needs a full pull-out for maintenance.

Case 3: effluent channel grating

Over the alkaline effluent channel, steel covers had corroded at the liquid line and were shedding rust into the flow. We supplied 38 mm molded grating in vinyl ester with concave surface, seated in the existing concrete channel edges, split into lift-out sections with SS316 handles. Concave washes clean when the channel is hosed down during the monthly cleaning, and the open mesh lets operators see the liquor level and any sludge build-up below. No rust runs down the channel wall anymore, which had to be scrubbed every quarter.

Product selection, maintenance and specifications

Product types and resin selection

In a bleach plant the resin rule is clear: vinyl ester wherever chlorine dioxide, caustic or hot liquor lands directly on the mesh. Isophthalic polyester stays on non-process walkways outside the building. Molded 38 mm with grit top covers the damp, high-slip washer floors; pultruded I-profiles at 50 mm cover the long spans around the ClO2 cabinet; concave molded covers the effluent channel. Clips are SS316, and every cut edge is sealed with vinyl ester so hot liquor cannot wick into the glass bundle. Phenolic is held back for fire-rated routes, not needed here.

Maintenance and service life

FRP in a bleach plant needs no painting, but the monthly channel clean is the right moment to walk the panels. Operators rinse the mesh with low-pressure water during the wash-down, check clip torque, and look for chipped edge seal where the liquor line sits. Expected life in bleach and chlorine dioxide service is 20 years or more, against two to three years for galvanized steel and five years for stainless. Pre-cut replacement sections ship flat-packed from Nantong, and a swap is a clip-out, clip-in job with no hot work.

How to start your project

Send us three items: a sketch of the walkway or platform with spans, the liquor list with concentrations and temperatures (ClO2 strength, caustic %, max liquor temp), and the surface and slip requirement. We check the span against the load table, confirm vinyl ester against the chemical list, and send resin coupons soaked in the customer liquor for the lab to inspect before mass production. For Brazilian pulp buyers we pack Portuguese-facing documentation alongside the ISO 9001 certificate.

Standard specifications and delivery

Molded panels ship at 1220 by 3660 mm, in 25, 30, 38, 38x40, 50 and 65 mm depths, mesh 38x38 or 50x50. Pultruded T and I profiles come in 25, 38, 50 and 76 mm depths. MOQ is 10 m2 and lead time runs 12 to 36 working days depending on resin thickness. Oversized panels, custom colours, new moulds and specialty resins are quoted with a separately confirmed schedule. Each order ships with ISO 9001 certificate 01708Q11888R0S, the ASTM F3059 report 211122012SHF-001, and SGS reports on request. Panels are banded into packs sized for the mill gate and local truck access.

Key takeaways

Three points close the case. First, bleach chemistry kills steel in two to three years; vinyl ester FRP is specified for 20 years or more on the same liquor. Second, chlorine dioxide zones need non-sparking pultruded profiles, not heavier steel platforms. Third, 38 mm vinyl ester molded at 19.5 kg per square meter carries 12 kN per square meter at 900 mm span, which covers the washer walkways and channel covers without a structural redesign.For the technical background see Corrosion-proof FRP for Brazilian mining and pulp and Chlorine-proof FRP for pulp and hydropower.
Which resin survives chlorine dioxide and hot caustic?
Vinyl ester. Isophthalic polyester is not rated for direct contact with ClO2 liquor or hot caustic extraction stage, even if it costs less per square meter.
Can FRP be used in a chlorine dioxide zone?
Yes. Vinyl ester pultruded and molded FRP is non-sparking and chemically compatible, which is why it replaces stainless in ClO2 cabinets and bleach washers. We supply the chemical resistance sheet with the order.
How long does FRP last in a bleach plant?
Expected life is 20 years or more in bleach and ClO2 service, compared with two to three years for galvanized steel and five years for stainless steel in the same liquor.
ZEALL Engineer

FRP Grating Technical Team

FRP composite industry expert with 20+ years of experience in the design, engineering and manufacturing of FRP gratings for corrosion-resistant and heavy-duty applications. Published by NANTONG ZEALL NEW MATERIALS CO., LTD.

Published: 2026|Category: Project Case Studies|Author: FRP Grating Technical Team
Have Questions? Contact Us →
Previous Article
FRP Grating Marine Offshore Projects
📞 Contact UsHomeProductsCatalogueApplicationsProjectsMarketsBlog🎬 VideosTools💰 CalculatorAbout

Project background

This case covers an FRP grating supply for a Brazilian eucalyptus pulp mill in the Southeast. The mill runs chlorine dioxide, hot caustic soda and bleach liquor on the same floor, with tropical humidity that never fully dries out. Three corrosive spots had been failing under steel: the walkways around the bleach plant washers, the platform at the chlorine dioxide supply cabinet, and the grating over the alkaline effluent channel.

On the original steel grating the bleach chemistry and the ClO2 cabinet atmosphere ate through the bar ends and the bearing edges in two to three years, and each panel swap demanded a tank-farm shutdown that the mill could rarely book. The client asked for a corrosion-resistant composite alternative that would run without a paint cycle, without hot-work permits and without pulling the washers offline during the monthly bleach wash-down.

Grating specification and load design

The panels supplied are 38 mm molded FRP grating in vinyl ester resin with a grit top, at a face weight of 19.5 kg/m2. The vinyl ester system is selected because the bleach area sees both acid (chlorine dioxide side) and hot caustic on the same walkway, which is the classic resin-selection rule for pulp bleach plants. Standard panel size is 1220 x 3660 mm; a 38 mm full panel weighs about 87 kg.

For walkways and platforms the sections are sized as simply supported single spans at L/200 deflection, rated for pedestrian and inspection loading. The molded 38 mm load table gives roughly 25 kN/m2 uniformly distributed at a 600 mm span, 12 kN/m2 at 900 mm and 6.5 kN/m2 at 1200 mm; heavier trolley or bundle loads are quoted case by case against that table, and pultruded profiles are offered where a longer span is needed. Fixings are SS316 clips, chosen because carbon-steel fasteners would themselves corrode in the bleach atmosphere.

ItemValue supplied
Resin systemvinyl ester (corrosion-grade)
Panel thickness38 mm molded
Surfacegrit top
Face weight19.5 kg/m2
Design load (900 mm span)12 kN/m2 (L/200, pedestrian / inspection)
FixingsSS316 clips
Standard panel1220 x 3660 mm (~87 kg)

Installation and site practice

On site the panels are carried by steel or pultruded FRP support beams, with the beam spacing set so the 38 mm panel sits within the 900 mm design span. Panels are seated on neoprene strips and fixed with two SS316 clips per beam per panel, one near each corner; this is the standard practice for walked-on gratings in chloride and bleach zones and avoids drilling carbon steel into the bearing.

Cutting to field dimensions and holes around nozzles, valve wheels and handrail posts are done on site with an abrasive saw or hole cutter, and cut edges are sealed with the matching vinyl ester gel to keep the glass fibres encapsulated. Handrails and toe kicks, where required by the layout, are matched pultruded FRP tubes bolted to the panel edge or to a separate stanchion. Because a full panel is light, installers carry it by hand rather than booking a crane, which matters inside a bleach building where headroom is tight.

  • Support beams: sized to the 900 mm design span, neoprene bearing strips under every panel
  • Fixing: SS316 clips, two per beam per panel, no welding to the structure
  • Cutting and holes: field cutting with abrasive tool, edges re-sealed with vinyl ester gel
  • Handrail / toe kick: pultruded FRP tubes, bolted, no metal embedded in the walkway surface

Delivery scope and acceptance points

The page does not publish a quantified outcome such as installed square metres, on-time delivery percentage or a multi-year service-life measurement. This page does not reproduce a customer quote or a measured field value, because the source page does not disclose one. The delivery scope that can be verified is the replacement of the three routes named above with 38 mm molded vinyl ester panels, fixed with SS316 clips so that no carbon-steel fastener remains in the bleach and ClO2 zone.

The technical targets the client would normally check at acceptance are: flatness and clip torque on every panel, non-slip performance of the grit top under wet foot traffic, absence of metal contact in the bleach / caustic / ClO2 atmosphere, and fit-up around nozzles and rail posts. Delivery is organised around the mill's planned annual shutdown window so that panel swaps do not extend beyond the booked isolation.

Common failure modes in this industry and how to prevent them

1. Hot and humid conditions (60°C, 90% RH) in bleach plants hydrolyse polyester resin, turning the surface soft and tacky.

Softened resin picks up pulp fibre, and the surface becomes rough and non-slip in a bad way. Flexural strength drops 20% in 2-3 years.

Specify vinyl ester resin for bleach plant and digester areas. Isophthalic only in machine house where temperature stays below 45°C. Annual Barcol check.

2. Bleach chemicals (chlorine dioxide, hydrogen peroxide, caustic) splash on walkway bars and etch the resin surface.

Etched bars hold pulp fibre and lime dust, building up a layer that adds dead load and traps moisture against the bar.

Use vinyl ester for all bleach preparation areas. Schedule quarterly high-pressure washing to remove fibre build-up. Inspect bars for pitting at each shutdown.

3. Wood pulp fibres and fines block open mesh gaps over 6-12 months, turning an open grating into a solid, slip-prone surface.

Blocked gaps hold water and fibre; the surface becomes a microbial slime and a slip hazard. Blocked bars also hide corrosion of clips.

Specify minimesh (13x13 mm) in pulp handling areas. For open mesh, schedule semi-annual jetting. Ensure clips are reachable for inspection despite fibre build-up.

4. Steam and condensate from digesters and bleach towers keep panels wet; thermal cycling (20-80°C) causes expansion delamination.

Repeated thermal cycling delaminates the bar from the bearing bar, creating a visible gap and eventual bar pop-out.

Use vinyl ester with high-temperature resistance (HDT >100°C). Allow for thermal expansion in clip design (slotted holes). Inspect joints at each annual shutdown.

Failure mode Trigger condition Prevention parameters
Resin hydrolysis Bleach plant 60°C / 90% RH Vinyl ester; Isophthalic only <45°C; annual Barcol
Bleach chemical etching ClO2 / H2O2 / caustic splash Vinyl ester; quarterly wash; pitting inspection
Fibre blockage Open mesh, 6-12 months pulp Minimesh 13x13 mm; semi-annual jetting; accessible clips
Thermal delamination Steam 20-80°C cycling Vinyl ester HDT >100°C; slotted clip holes; annual joint check

Related product family and further reading

This case sits inside the molded 38 mm vinyl ester FRP grating family (grit top, corrosion-grade resin), supported by the matching pultruded FRP profiles for frames and handrails, the SS316 clip range, and custom cutting for irregular openings around nozzles and valve stations. For the effluent channel cover the same resin system is also available as trench cover grating and as FRP plate. The links below open the product pages and the adjacent case studies on this site.

Document Preview

Preview mode · For full document, click Download

Download Document

Thank you for your interest. Please fill in your email and company name. Our technical and sales team will contact you within 30 minutes (during working hours) to provide support!

📧 Your information will be sent to sales@gratingfrp.com. We respect your privacy and will never share your data.

Thank You!

Your request has been received successfully.

Our technical and sales team will contact you within 30 minutes (during working hours) to provide the document and professional support!

If you need urgent assistance, please email: sales@gratingfrp.com