📞 Contact UsHomeProductsCatalogueApplicationsProjectsMarketsBlog🎬 VideosTools💰 CalculatorAbout
Direct GRP Grating Manufacturer · Nantong, China · UK & Commonwealth Specs

GRP Grating Panels

Moulded and pultruded GRP grating panels in 25–60 mm thickness, supplied to BS 4592 and BS EN 13706 from a factory that has exported to the UK, Ireland, Australia, the Gulf and 45+ countries for over 20 years.

ISO 9001 CertifiedBS 4592 & EN 1370645+ Countries20+ YearsOEM / ODM Support
GRP Grating Panels

What Is a GRP Grating Panel?

A GRP grating panel is an open-mesh, load-bearing floor panel made from glass fibre reinforcement set in a thermoset resin. GRP stands for Glass Reinforced Plastic — the term used throughout the United Kingdom, Ireland, Australia, New Zealand and the Gulf states for the same composite material that North American buyers call FRP (Fibreglass Reinforced Plastic).

The panel is produced by one of two processes. Moulded GRP grating is made by pouring resin and chopped glass strand into a heated matched metal mould, producing a one-piece panel with an integral anti-slip surface and no joints to work loose. Pultruded GRP grating is made by pulling continuous glass roving through a heated die to form interlocking I-bars and T-bars, which is how you get panels capable of clear spans of 1.2 m and beyond.

Both types share the properties that make GRP the default flooring choice in aggressive environments: it does not rust, it does not rot, it is non-conductive, it is roughly one quarter the weight of an equivalent steel grating, and it needs no painting or galvanic protection over a 20-year service life. A 38 mm moulded panel weighs about 19.5 kg/m² on a standard 1220 x 3660 mm footprint (about 87 kg for the full panel), so a two-man team can carry cut panels that would need a crane in steel.

GRP vs FRP: they are the same product, not different grades. A specification that says GRP grating in Birmingham and one that says FRP grating in Houston are asking for the same panel. What changes by market is the standard cited, the resin system favoured for local UV and temperature conditions, and the certification the buyer needs for sign-off. Those three things are what this page is built around.

Terminology

GRP Grating Panel, GRP Grate and GRP Grating — One Product

Buyers arrive at this page through three spellings: GRP grating panel, GRP grate, and GRP grating. All three describe the same open-grid composite floor panel. A grate is the flat panel itself; grating is the panel system including the bearer bars and the clips that hold it down. A panel is one manufactured sheet, typically 1 m x 2 m, 1 m x 3 m or 1.22 m x 2.44 m before cutting.

If your drawing, bill of quantities or tender document uses any of these terms, you are in the right place. We quote against the drawing, not against the word. Send a panel schedule with thickness, mesh size, resin type and quantity and you will get a line-by-line price back, cut to size where required.

Two further terms appear in UK specifications and are worth separating. GRP open mesh flooring is the same product described by its function rather than its material — the phrase tends to be used by safety and access engineers rather than by composite suppliers. GRP floor grating and GRP platform grating are application-led names for the identical panel installed on a walkway or a platform deck.

Construction Types

Moulded and Pultruded GRP Grating Panels

M

Moulded GRP Grating Panels

Resin and chopped strand poured into a matched mould under heat and pressure. The result is a single-piece panel with a concave or gritted walking surface, equal strength in both directions, and no mechanical joints. Standard mesh 38 x 38 mm or 40 x 40 mm, thickness 25, 30, 38 or 50 mm.

Use it for: walkways, access platforms, stair treads, trench covers, machine guards, and anywhere a panel has to be cut and fitted on site without losing strength at the cut edge.

P

Pultruded GRP Grating Panels

Continuous glass roving pulled through a heated die to form I-bars and T-bars, then assembled and locked with resin. The unidirectional reinforcement aligned with the load path gives far higher stiffness per kilogram, which is what buys the long span.

Use it for: spans over 1.2 m, offshore modules, cooling tower decks, chemical plant platforms and anywhere deflection governs the design.

C

GRP Grating Clips and Fixings

M, C, L and Z clips in SS304 and SS316 to lock panels to bearer bars, plus bolting and pedestal options. Correct clip selection is what stops panel lift under wind and traffic, and it is specified alongside the panel, not after it.

Specifications

GRP Grating Panel Sizes, Thickness and Weight

The table below gives the standard moulded GRP panel range we hold tooling for. Anything outside it can be custom moulded, but lead time moves from stock to production.

Panel typeMesh (mm)Thickness (mm)Weight (kg/m²)Bar depth (mm)Typical clear span
Standard moulded38 x 382512.525600 mm
Standard moulded38 x 383015.030750 mm
Standard moulded38 x 383819.538900 mm
Standard moulded40 x 403818.038900 mm
Standard moulded50 x 505027.0501200 mm
Heavy moulded50 x 506538.0651200 mm
Pultruded T-bar38 x 38257.5 to 9.5251200 mm
Pultruded I-bar38 x 383812.5 to 14.5381800 mm
Pultruded T-bar50 x 505015 to 17502400 mm

Standard panel footprints are 1000 x 2000 mm, 1000 x 3000 mm, 1220 x 2440 mm and 1220 x 3660 mm. Panels are cut on a diamond saw; a cut panel keeps its full section because the bar is solid through the thickness, which is why moulded GRP is the friendlier option when a site has awkward openings.

Density works out at roughly 1.5–2.0 g/cm³ depending on resin and glass content, against 7.8 g/cm³ for carbon steel. Barcol hardness on a sound panel is 40 or above. These are the figures a checking engineer will ask for first.

Structural Data

Load, Span and Deflection for GRP Panels

GRP is a deflection-governed material, not a strength-governed one. In almost every real design the panel does not fail — it sags enough to fail the serviceability limit first. That single fact decides thickness far more often than the load figure does.

As a working guide for a uniformly distributed load on a moulded panel simply supported at both ends, with deflection limited to L/150:

Thickness600 mm span900 mm span1200 mm span
25 mm3.5 kPa1.5 kPa—
30 mm5.0 kPa2.2 kPa—
38 mm7.5 kPa3.3 kPa1.8 kPa
50 mm12.0 kPa5.3 kPa2.9 kPa

Point loads behave differently and are usually the governing case on a walkway, because a 100 kg foot on a 38 mm bar is nothing like a uniform pressure. For a 0.1 m x 0.1 m contact area, a 38 mm moulded panel on a 900 mm span carries roughly 2.7 kN before the deflection limit bites. Concentrated loads from trolleys, pallet trucks and maintenance equipment should be checked individually rather than read off a uniform-load table.

For anything above 1.2 m clear span, move to pultruded. For spans past 2.4 m, add intermediate bearer bars — the panel is not the place to solve a long span. Send the span, the load and the deflection limit and we will run the section for you; that calculation is free and it is the part most buyers get wrong.

Resin Systems

Choosing Resin for UK and Northern European Conditions

Resin choice decides service life more than thickness does. Four systems cover almost every UK and Irish specification.

Isophthalic Polyester (ISO)

The default for general industrial and municipal work. Good water resistance, works to about 90 °C, and is the cheapest system that still meets a normal 20-year expectation. Specify it for walkways, drainage covers and non-chemical platforms.

Orthophthalic (Ortho)

Lower cost, lower chemical resistance. Fine for dry indoor access panels and lightweight covers where no aggressive exposure exists. Not the resin to put over a chemical bund or a coastal deck.

Vinyl Ester (VE)

The one to specify where chlorides, acids or hypochlorite are present — water treatment, desalination, coastal and offshore. Handles roughly 120 °C and has markedly better resistance to hydrolysis than polyester.

Phenolic

For fire-critical locations and for anything needing low smoke and low toxicity in a fire. Suitable up to about 150 °C. Specify phenolic where the fire strategy calls for limited combustibility rather than where cost matters.

UV stability is a separate question from resin chemistry. For panels exposed to northern European weather, a UV-stabilised topcoat or an integral UV inhibitor is what stops surface chalking and glass print-through after three or four summers. Coastal and high-altitude sites need the better of the two. Ask for it explicitly in the specification — it is a small cost and a large difference at year ten.

Compliance

UK Standards and Certification for GRP Grating

This is where a UK or Irish buyer's approval process actually lives, and it is where most overseas suppliers fall down. The standards you are likely to be held to:

  • BS 4592-1:2006 — Industrial type flooring, walkways and stair treads. Covers dimensional and performance requirements for metal and composite grating, including the loading classes used in UK industrial specification.
  • BS EN 13706 — Specification for pultruded profiles. Governs the mechanical property grades (E17, E23) used when a pultruded GRP panel is specified structurally.
  • BS EN 124 — Gully and manhole tops for vehicular and pedestrian areas. Applies where a GRP trench cover or access cover carries a traffic class.
  • EN 13501-1 — Fire classification. Phenolic systems reach B-s1,d0; polyester systems typically land at E or D. This decides whether the panel is acceptable in a covered structure or an escape route.
  • DIN 51130 — Ramp test for slip resistance. Gritted GRP surfaces normally achieve R11 to R13, which is what underwrites the anti-slip claim in a tender.
  • ISO 9001 — Quality management. Ours is certified and auditable; ask for the certificate number and check it, because a certificate that cannot be verified is worth nothing in an approval pack.

Two practical notes. First, a GRP panel sold into the UK does not carry a CE mark as a grating — there is no harmonised European product standard for grating as such, so be sceptical of a supplier who claims one. What is real is BS EN 13706 for the pultruded profile, EN 13501-1 for fire, and third-party load test reports. Second, for projects under a building control or CDM regime, the useful deliverable is a documented load calculation plus resin datasheet plus fire classification, not a marketing page. We issue all three with the quotation.

Applications

Where GRP Grating Panels Are Specified in the UK

The pattern of use in the UK and Ireland is fairly consistent, and it tells you what to expect from a specification.

Walkways and Access Platforms

Water industry sites are the single biggest UK market — sewage treatment works, pumping stations, sludge handling. Vinyl ester resin, gritted surface, 38 mm moulded as standard. Anglian, Thames and Severn Trent style specifications usually call BS 4592 loading classes.

Trench Covers and Drainage

Drainage channels in chemical plants, food factories and plant rooms. Frequently specified with a slip-resistant finish and a matching clip system so the cover cannot be lifted by wind or wash-down.

Stair Treads and Ladders

Stair treads, ladder rungs and crossover stairs. 25 mm and 30 mm panels are the common sizes; nosing and tread profile matter as much as the panel itself for a safe stair under UK HSE expectations.

Offshore, Wind and Marine

Wind turbine access platforms, offshore module decks, jetty walkways. Vinyl ester throughout, pultruded where spans run long, and a documented chloride exposure story for the asset register.

Chemical and Pharmaceutical Plant

Bunding covers, mezzanine floors and tank farm access. Resin selection dominates here; hypochlorite and acid service point to vinyl ester or phenolic, not to a thicker polyester panel.

Food and Beverage

Wash-down areas needing a smooth, non-porous surface and cleanability between bars. Phenolic or food-grade ISO systems, with the mesh size chosen so that debris cannot collect.

Installation

Fixing and Installing GRP Grating Panels

GRP panels are light, which is the whole point, and light panels move under wind and traffic if they are not held correctly. Fixing is not a detail to settle on site.

Clipping. Panels sit on bearer bars, either GRP pultruded beams or steel sections, and are held by M, C, L or Z clips at four points per panel minimum, more on exposed walkways. Only one clip per fixing point — a stack of clips is a symptom of an install problem, not a solution. Space clips at roughly 1 m centres along a bearer and always at both ends of a cut panel.

Bolting. Where panels must resist uplift or a vehicle wheel, bolt through the bar into the bearer with stainless fixings and a load-spreading washer. Do not overtighten; GRP is a composite and a crushed bar is a lost section. Torque to the supplier's figure, not to feel.

Thermal movement. GRP expands and contracts roughly 2–3 times as much as steel over the same temperature change. On a long run, leave a movement gap between panels and allow for it at the perimeter, or the panels will tent in summer and crack in winter. A 6 mm gap per 3 m run is a reasonable starting allowance for a UK external deck.

Cutting on site. Diamond blade or abrasive disc, low speed, no heat. Do not drill through a bar with a hammer drill set to hammer mode — it delaminates the bar and the panel loses its section exactly where it was fixed.

Handling. Wear gloves. Freshly cut GRP edges leave glass fibre exposed; a file or a sealant coat on the cut edge is good practice on any panel a person will handle.

Cost

UK Distributor Price vs Factory-Direct GRP Panels

The UK GRP market is supplied largely through distributors and stockists who buy from European or Asian manufacturers, hold stock locally and add margin plus the cost of carrying that stock. That structure buys you next-day availability and a UK point of contact. It also sets a price floor that a direct factory supply does not have.

For a comparable 38 mm moulded, vinyl ester, gritted GRP panel in reasonable quantity, the factory-direct route typically lands materially below a UK stockist list price even after freight, duty and clearance — the difference is the distributor margin, not a difference in the panel. On small quantities the gap narrows, because freight stops being spread. On a project quantity with a panel schedule it widens.

What you give up going direct is immediate local stock and a UK-based account manager standing on your site. What you keep is full traceability to the mould, a resin datasheet matched to your exposure, and the ability to have the panel made to your drawing rather than cut from a stock size. If the project cannot absorb a sea-freight lead time, a UK stockist is the honest answer; if it can, direct supply is usually the better commercial position.

We will not pretend to be a UK company. We are a manufacturer in Nantong, China, exporting into the UK and Irish markets, and the quotation states the lead time, the Incoterm and the certification pack plainly so that the comparison against a UK distributor is like for like.

Related

Related GRP and GRP/FRP Pages

More GRP guides: GRP grating price · GRP grating clips · GRP walkway grating · GRP trench cover grating · GRP stair tread grating

GRP Grating — Full Range

The complete GRP grating overview: moulded and pultruded, resin options, standards by market, and the terminology that surrounds the product.

GRP Grating Manufacturer

Who makes it, from which mould, under which quality system, and what an approval pack from a Chinese GRP manufacturer actually contains.

Heavy Duty GRP Grating

50 mm and 60 mm panels, traffic classes, and the load cases where a standard panel is simply not enough.

FRP Grating Panels

The same panel under its North American name, for buyers working to US or ASTM specifications.

GRP Structural Profiles

Pultruded beams, channels and angles to support a GRP deck, specified to BS EN 13706 grades.

GRP and FRP Grating Price Guide

What drives the price per square metre, how quantity breaks work, and what to include in a like-for-like comparison.

GRP Platform Grating

Load classes, mesh, thickness and the bearer spacing a platform deck needs, with the working-load figures behind each class.

GRP Channel Grating

Trench, duct and drainage covers from A15 to C250, with open area, resin choice for corrosive runs and cut-to-channel-width supply.

GRP Catwalk

Modular elevated walkway kits: deck, pultruded frames and handrail, installed by hand without a crane or hot work.

GRP Grating Suppliers

Twelve checks for comparing suppliers, from resin system and glass content to certification and a dated lead time.

GRP Grating Supplier

Supply terms, MOQ, lead times, Incoterms, documentation pack and sea freight transit times.

FAQ

GRP Grating Panels — Frequently Asked Questions

Is GRP grating the same as FRP grating?

Yes. GRP (Glass Reinforced Plastic) and FRP (Fibreglass Reinforced Plastic) name the same composite material and the same panel. GRP is the standard term in the UK, Ireland, Australia and the Gulf; FRP dominates in North America and in most international tender documents. Nothing in the product changes with the name — only the standard cited and the resin usually specified for local conditions.

What thickness of GRP grating panel do I need?

Thickness is set by span and by the deflection limit, not by the load alone. For a 600 mm span, 25 mm is normally adequate. At 900 mm, 38 mm is the working choice. At 1200 mm and beyond, move to pultruded or add bearer support. Send the span, load and deflection limit and we will size it properly — guessing thickness is the most common cause of a failed walkway inspection.

Does GRP grating meet BS 4592?

GRP grating panels can be supplied to meet BS 4592-1:2006 loading and dimensional requirements, and pultruded panels to BS EN 13706 grades. What matters in an approval pack is the documented load calculation, the resin datasheet and a fire classification to EN 13501-1. We issue all three with the quotation on request.

Is GRP grating slip resistant?

A gritted GRP surface typically reaches R11 to R13 under the DIN 51130 ramp test, which is the classification UK and European specifications usually call for on a walkway or a stair. A smooth moulded concave surface is anti-slip but not ramp-tested to the same class. If the specification names an R class, order the gritted finish.

What is the maximum span for a GRP grating panel?

Around 900 mm for a 38 mm moulded panel with deflection at L/150, about 1.2 m for the same panel at a looser limit, and up to 2.4 m for a 50 mm pultruded T-bar. Beyond that the panel is not the answer — add intermediate bearers. The governing check is almost always deflection rather than strength.

How much does a GRP grating panel weigh?

A 38 mm moulded panel on 38 x 38 mesh weighs about 19.5 kg/m²; a 25 mm panel about 12.5 kg/m²; a 50 mm panel about 27.0 kg/m². Pultruded panels are lighter for the same depth, at roughly 7.5 to 9.5 kg/m² for a 25 mm T-bar, depending on open area. For comparison, an equivalent steel grating is around four times the weight, which is the practical reason GRP gets used on retrofits where the structure cannot take extra dead load.

Which resin should I specify for a UK site?

Isophthalic polyester for general industrial and municipal work. Vinyl ester where chlorides, acids or hypochlorite are present — water treatment, coastal and offshore. Phenolic where the fire strategy requires limited combustibility or low smoke. Orthophthalic only for dry indoor work with no chemical exposure.

Can GRP grating panels be cut on site?

Yes, with a diamond blade or abrasive disc at low speed. A moulded panel keeps its full section at the cut because the bar is solid through the thickness, which is why moulded is the easier option for awkward openings. Pultruded panels also cut cleanly but the cut exposes the bar end, so seal it if the location is wet or chemical.

How long does GRP grating last?

A properly specified panel gives 20 years or more in normal industrial service. Service life is decided by resin choice and UV protection far more than by thickness. A UV-stabilised vinyl ester panel on a coastal deck will outlast a cheaper polyester panel in the same place by a wide margin. Maintenance is effectively washing, plus an annual check that clips have not loosened.

Do you supply to the UK and Ireland?

Yes. We have exported to the UK, Ireland, Australia, the Gulf and 45+ countries for over 20 years. Quotations state the Incoterm, the lead time and the certification pack plainly. Typical sea freight to a UK port runs several weeks depending on routing, so plan the programme around it rather than assuming local stock.

What is the price per square metre?

Price depends on thickness, mesh, resin system, surface finish, quantity, cut-to-size work and freight. A 38 mm moulded isophthalic panel in project quantity sits in a different band from a 50 mm vinyl ester gritted panel in small quantity. Send a panel schedule and you will get an itemised price rather than a headline rate that cannot be compared.

Can you make panels to my drawing?

Yes. Custom mesh, thickness, panel size, colour, resin and surface finish are all available, and we hold tooling for the common UK sizes. Custom moulding moves the lead time from stock to production, so it is worth confirming early in the programme rather than after the steel is up.

What fixings do I need with the panels?

M, C, L or Z clips in SS304 or SS316, at four points per panel minimum and at both ends of every cut panel, spaced roughly 1 m along a bearer. Where uplift or wheel load applies, bolt through the bar with stainless fixings and a load-spreading washer, torqued to the supplier's figure. Clips are quoted with the panel, not sourced separately on site.

Next Step

Request a GRP Grating Panel Quotation

Send the panel schedule, the span and the exposure conditions. You will get an itemised quotation, a load calculation where the design needs one, and a resin recommendation matched to the site — from a factory that has been supplying GRP and FRP grating into export markets for over 20 years.

Request a Quote → GRP Grating Calculator

NANTONG ZEALL NEW MATERIALS CO., LTD. · Direct manufacturer · ISO 9001 · BS 4592 / BS EN 13706 documentation on request

Document Preview

Preview mode · For full document, click Download

Download Document

Thank you for your interest. Please fill in your email and company name. Our technical and sales team will contact you within 30 minutes (during working hours) to provide support!

📧 Your information will be sent to sales@gratingfrp.com. We respect your privacy and will never share your data.

Thank You!

Your request has been received successfully.

Our technical and sales team will contact you within 30 minutes (during working hours) to provide the document and professional support!

If you need urgent assistance, please email: sales@gratingfrp.com